Keyence Visual KV Series Manual de usuario Pagina 244

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 444
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 243
6.3 Functions
Chapter 6 Handheld Programmer
1-220
6
PROGRAM SENT OR RECEIVED PROGRAM mode OFFLINE EDITOR
(COMMUNICATION —) [FNC66]
Function
Writes program on handheld programmer [KV-P3E(01)] into KV, reads program in
KV onto handheld programmer, or verifies program (compares programs on pro-
grammer and on PLC).
When the KV is read-disabled, READ and VERIFY cannot be executed.
WRITE: KV-P3E(01) – Program KV
READ: KV-P3E(01) Program – KV
Key operation
Basic operation
Example of operation (for executing VERIFY)
The program is also automatically read both when the handheld programmer
[KV-P3E(01)] is connected to the Visual KV and when OFFLINE EDITOR is
quitted.
The program is also automatically written and verified when the handheld pro-
grammer is switched from the PROGRAM mode to the RUN mode.
BASE WRITE
->READ VERIFY
ON
ORB
6
ORB
6
ENT
R-SRCH
FNC
OFF
BASE ->WRITE
READ VERIFY
ON
OFF
Read
Write
BASE WRITE
READ ->VERIFY
Verify
OFF
ON
ENT
R-SRCH
ENT
R-SRCH
Key operation Display Description
00000
Display arbitrary line.
LD 00000
BASE U. WRITE Access PROGRAM SENT OR RECEIVED
->READ VERIFY [COMMUNICATION...] function.
BASE U. WRITE
Select VERIFY.
READ ->VERIFY
VERIFY W/BASE U.
Execute VERIFY of program.
EXEC. OK?
VERIFY OK
PUSH CLR TO CON
00000
Return to initial display.
LD 00000
FNC
ORB
6
ENT
R-SRCH
CLEAR
ENT
R-SRCH
ORB
6
ON
ENT
R-SRCH
KVHKA Chap 06_3&4&5.p65 08.3.11, 11:17 AM220