3-6
3
LK-G-M-NO3-E
3 Function Settings
Setting procedure of ABLE (MANUAL)
1
Hold down the
key, and select "
kEAd-A
" with the
key.
"Head A" is set in this example.
2
Press the key, and select function "
A
" with the key.
Set ABLE.
3
Press the
key, and select "A-1" with the
key.
Select "ìmanual".
4
Press the
key, and set the value for the higher limit
with the
and
keys.
"60" is set in this example.
5
Press the
key, and set the value for the lower limit with
the
and
keys.
"20" is set in this example.
6
Press the
key to register the setting. Press the
key to return to the measurement state.
OUT1
HI GO LO
HI GO LO
TIM
OUT2
TIM
HI GO LO
OUT2
TIM
OUT1
HI GO LO TIM
OUT1
HI GO LO
HI GO LO
TIM
OUT2
TIM
OUT1
HI GO LO
HI GO LO
TIM
OUT2
TIM
OUT1
HI GO LO
HI GO LO
TIM
OUT2
TIM