LK-G-M-NO1-E
1 Before Use
LK-G35/LK-G30/LK-G37/LK-G32
The measurement range is shown in the figure below.
* The value inside the parentheses ( ) is when the sampling rate is 20 µs.
• The laser emission LED at both diffuse reflection and specular reflection lights in
green within ±0.25 mm of the reference position, and lights in orange in the other
positions in the measurement range.
M4r35 mm or more
Installation procedure
Diffuse reflection setup Specular reflection setup
Reference
distance
30 mm
Reference
distance
0 mm
Reference
distance
23.5 mm
Reference
distance
0 mm
+4.5mm
Measurement range
–4.5mm
(–1.6 mm)
+5mm
Measurement range
–5 mm
(–1.8 mm)
40°
Reference
Vista de pagina 29