3-47
3
LK-G-M-NO3-E
3 Function Settings
List of Default Values and Setting Ranges
The function settings (default) at the time of shipment and the settable ranges are as follows.
Function Item Settable range Default value Remarks
A
Baud rate 9600/19200/38400/57600/115200 bps 9600 bps
Parity NON/EVEN/ODD NON
Auto transmission OFF/OUT1/OUT2/OUT1.2 OFF
b
Setting Selection Panel operation/external terminal Panel
operation
Program Copy/initialization
d
Panel lock ON/OFF OFF
E
Eco mode None/Eco-half/Eco-all None