4 Input/Output Terminals
LASER REMOTE/LASER OFF
*
T6 is a sampling rate. ( page 3-39)
T2 is the input response time.( page 4-17)
The alarm status can be changed with the alarm settings ( page 3-8).
As for the REMOTE input, the open state is ON, and the short-circuited state is OFF.
As for the LASER OFF A/B input, the open state is OFF, and the short-circuited state is ON for NPN type.
For PNP type, ON when the voltage is applied and OFF for the open state.
Emit
Stop
Laser emission
Measurement value
ON
T2
Measurement Alarm Measurement
T2
T6×6
OFF
REMOTE input
LASER OFF A/B input