4 Input/Output Terminals
The following table shows a list of program numbers and how they relate to the status of
terminals P1 through P3 :
When you change the program number via an input/output terminal, [Setting Selection] in
the Environment settings should be changed to [Terminal Input].
Binary output
Program No. P3 P2 P1
0 OFF OFF OFF
1 OFF OFF ON
2 OFF ON OFF
3 OFF ON ON
4 ON OFF OFF
5 ON OFF ON
6 ON ON OFF
7 ONONON
S
tatus
NPN type PNP type
ON Short-circuit state with the
COM terminal
State of voltage applied
OFF Open state Open state
Refer to "Setting the Program Switching Method" (page 3-50) for details.
Name Description Reference
page
Binary output Outputs the measured value as binary data.
Outputs two’s complement in 21 bits.
Negative logic (1 when the NPN or PNP open-collector
output is ON)
Comparator standby status (all digits have a negative
(–) sign) : 0x100000
Over range at positive side : 0xOFFFFF
Over range at negative side : 0x100000
Alarm : 0x100000
Page 4-6
STROBE output Strobe output of the binary output Page 4-6
OUT1/OUT2 OUT output You can identify through which OUT number the data is
currently being output.
OFF: OUT1
ON: OUT2
Page 4-6
OUT1/OUT2 SEL input Select the OUT number to output in binary.
OFF: OUT1
ON: OUT2
Page 4-6