5-23
5
LK-G-M-NO5-E
5 RS-232C
Timing Chart
When the measurement mode is other than sample hold (trigger 2)
When the measurement mode is set to normal, the measurement value of when the timing
input turns on is outputted.
When the measurement mode is peak hold, bottom hold, peak-to-peak hold, average
hold or sample hold (trigger 1), the measurement value that is fixed by turning on the
timing input is outputted.
When the measurement hold is sample hold (trigger 2)
After the timing input turns on, the measurement value fixed after the sampling period
+t ms is outputted.
The t-time is identified as follows.
Sampling rate 20 µs t=T2+4 ms
Other than 20 µs t=T2+3 ms
Refer to page 4-16 for T2 (input response time).
TIMING input
Measurement
value
t ms
RS-232C data output
ON
OFF
TIMING input
Measurement
value
Sampling period + t ms
RS-232C data output
ON
OFF