Outputting Measurement Values and
Changing Settings through Commands
You can import the measurement value or change the parameters of the LK-G
Series by connecting it to a PC or PLC link unit.
Connecting the PC or PLC Link Unit
Combine the dedicated cables OP-96368 (2.5-m straight cord), OP-26401 (D-sub 9-pin),
or OP- 96369 (D-sub 25-pin) for connection.
Connection diagram
Refer to "Precautions for Wiring" (page 4) for details.
Environment Settings Parameters
Set the functions according to the PC or PLC link unit to be connected.
Refer to the instruction manual of the PC or PLC link unit at the time of connection.
Refer to "Setting the Communication Specifications of the RS-232C" (page 3-49).
Item Setting value Remarks
Baud rate 9600/19200/38400/57600/115200 Set the parameter according to the
external devices to be connected.
Parity check None/Even/Odd
RD (RXD)
SD (TXD)
ew
RD (RXD)
we
SG (GND)
tu
RS (RTS)
ur
CS (CTS)
it
DR (DSR)
y
q
y
CD (DCD)
i
ER (DTR)
r@0
t
SG (GND)
r
SD (TXD)
e
PC side
LK-G side
Signal name
OP-26401OP-96369
PLC link unit
PC
Note