2-14
Using the Displacement Mode
1
Adjust the height and position of the
measuring unit and fix the distance and
position relating to the measurement target.
How to adjust the distance between a
measurement target and the measuring unit.
It will be easier to adjust by combining the three
methods shown below.
1 Adjust the distance to obtain the smallest possible
red laser spot.
2 Adjust the distance to get the measurement target
into focus.
3 Adjust the distance while reading the light intensity
peaks graph on the light intensity screen.
Setting the scanning width/interval is described
next.
Reference
Adjusting the Distance Between the
Measuring Unit and the Measurement Target
1
Slide the [PROG/RUN] switch downward on
the remote control console to display the
program mode.
2
Select [BASIC] by using the [
] and [ ]
buttons and press the [Enter] button.
3
Place the cursor on [SCAN] by using the [
]
and [ ] buttons and press the [ENTER]
button.
4
Place the cursor on [SCAN WIDTH] by using
the [
] and [ ] buttons and press the
[ENTER] button
5
Select [120/2] by using the [
] and [ ]
buttons and press the [ENTER] button.
6
Slide the [PROG/RUN] switch downward on
the remote control console to display the run
mode screen.
Setting the scanning width/interval is completed.
Setting the light intensity level is described next.
Setting the Scanning Width/interval
E LT-9001-IM
Basic Operations