You can import the measured value or change the parameters of the LT-9001 Series by connecting it to a
PC or PLC link unit.
Sets the environment settings according to the PC or PLC link unit that is to be connected to the main unit.
The LT-9001 Series controls the incoming command that has been received and sends back the response
command to the external device. The [CR] is used as a delimiter of incoming and response command.
Incoming command format
Response command format
Error response command format
Outline of Command Format
Environment Settings Parameters
Outputting Measured Values and Changing Settings
by Using Commands
Item Parameter Remark
BAUDRATE 9600
/
14400
/
19200
/
38400
/
57600
/
115200bps
PARITY NONE
/
EVEN
/
ODD
Set the parameter according to the external
STOPBIT 1
/
2
devices to be connected.
D-LENGTH 7
/
8
D-MODE OFF
Select [OFF] for this item.