Vista de pagina 117
LO output for OUT2
GO output for OUT2
HI output for OUT2
LO output for OUT1
GO output for OUT1
HI output for OUT1
7-4
7
Identifying Names and Functions of the I/O Terminal
The signal names and descriptions of each terminal
The signal names and descriptions of each terminal are described as follows.
Refer to "Functions of the I/O Signals" (page 7-5) for the detailed functions.
Do not use the unused terminals. It may lead to breakdown of the unit.
Note
E LT-9001-IM
I/O Terminal
7
Chapter
Description
Terminal
Terminal name Binary output selected
Tolerance judgment
number output selected
1 P3
18 P2 Program No. change input
2 P1
19 LASER REMOTE Laser remote input
3 BIN SEL
Binary output content
Unused
selection input
20 COM2 COM for I/O
4 BIN STB/OUT STB Strobe output for binary
21 SCAN STB Strobe output for scanning
5 BIN OUT
Binary output content
selection output
22 Binary(0) LSB
6 Binary(1)
23 Binary(2)
Unused
7 Binary(3)
24 Binary(4) Binary output
8 Binary(5)
25 Binary(6)
9 Binary(7)
26 Binary(8)
10 COM2 COM for I/O
27 Binary(9)
11 Binary(10)
28 Binary(11)
Binary output Unused
12 Binary(12)
29 Binary(13)
13 Binary(14)
30 COM2 COM for I/O
14 Binary(15)/LO2
31 Binary(16)/GO2
15 Binary(17)/HI2
Binary output
32 Binary(18)/LO1
16 Binary(19)/GO1
33 Binary(20)MSB/HI1
17 STABILITY Stability output
34 COM2 COM for I/O
* COM2 of 10,20,30,34 is common.
* COM2 is common to COM1 of the terminal block.