Keyence LJ-V7000 Series Manual de usuario Pagina 75

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 94
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 74
75LJ-V7000_COM_RM_E
OUT settings
<Profile Mask area settings individual>
Type:10h~1Fh (10h:Program NO.0, 11h:Program NO.1,
・・・ , 1F:Program NO.15)
Category:05h, Item:02h
Target1:00h (headA/wide), 01h (headB)
Target2:00h~04h (Profile mask area1~5) Target3~4:00h
byte Setting Data
0 Area selection:0:Disabled, 1:Rectangle, 2:Triangle
1
position correction selection: 0: No position
correction, 1:Position correction1, 2:Position
correction2
2 Reserved (fixed as 0)
3 Reserved (fixed as 0)
4
Xcoordinate1: any value in measurement range
(0.01μm unit Sined 32-bit integer
example: 5mm=500000)
5
6
7
8
Zcoordinate1: any value in measurement range
(0.01μm unit Sined 32-bit integer
example: 5mm=500000)
9
10
11
12
Xcoordinate2: any value in measurement range
(0.01μm unit Sined 32-bit integer
example: 5mm=500000)
13
14
15
16
Zcoordinate2: any value in measurement range
(0.01μm unit Sined 32-bit integer
example: 5mm=500000)
17
18
19
20
Xcoordinate3: any value in measurement range
(0.01μm unit Sined 32-bit integer
example: 5mm=500000)
21
22
23
24
Zcoordinate3: any value in measurement range
(0.01μm unit Sined 32-bit integer
example: 5mm=500000)
25
26
27
* When Rectangle is selected, upper left (Xcoordinate1,
Zcoordinate1) and bottom right (Xcoordinate2,
Zcoordinate2) should be set. Xcoordinate3, Zcoordinate3 is
no effect.
* When Triangle is selected, (Xcoordinate1, Zcoordinate1),
(Xcoordinate2, Zcoordinate2) and (Xcoordinate3,
Zcoordinate3) are used.
<OUT name>
Type:10h~1Fh (10h:Program NO.0, 11h:Program NO.1,
・・・ , 1F:Program NO.15)
Category:06h, Item:01h
Target1:00h~0Fh (OUT1~16) Target2~4:00h
Byte Setting Data
0 OUT name, byte1
1 OUT name, byte2
2 OUT name, byte3
~~
19 OUT name, byte20
*20 Characters max. 0 is not appended to the end.
*SHIFT-JIS
<Minimum display unit>
Type:10h~1Fh (10h:Program NO.0, 11h:Program NO.1,
・・・ , 1F:Program NO.15)
Category:06h, Item:02h
Target1:00h~0Fh(OUT1~16) Target2~4:00h
byte Setting Data
0 Minimum display unit
1 Reserved (fixed as 0)
2 Reserved (fixed as 0)
3 Reserved (fixed as 0)
* The unit changes according to the measurement mode
assigned to the OUT.
Length system, 0:1mm, 1:0.1mm, 2:0.01mm, 3:0.001mm,
4:1μm, 5:0.1μm
Area system, 0:1mm
2
, 1:0.1mm
2
, 2:0.01mm
2
, 3:0.001mm
2
,
4:0.0001mm
2
, 5:0.00001mm
2
Angle system, 0:1deg, 1:0.1deg, 2:0.01deg
<Measurement mode>
Type:10h~1Fh (10h:Program NO.0, 11h:Program NO.1,
・・・ , 1F:Program NO.15)
Category:06h, Item:03h
Target1:00h~0Fh (OUT1~16) Target2~4:00h
byte Setting Data
0
Minimum display unit (from
)
1
Measurement mode (from
)
2 Reserved (fixed as 0)
3 Reserved (fixed as 0)
4 From 4byte, unique parameters are assigned to
each measurement mode. For details on the
unique parameters, see [Unique parameters of
measurement mode from 4byte]
~
N
Length system ・・・ 0:1mm, 1:0.1mm, 2:0.01mm,
3:0.001mm, 4:1μm, 5:0.1μm
Area system ・・・ 0:1mm
2
, 1:0.1mm
2
, 2:0.01mm
2
,
3:0.001mm
2
, 4:0.0001mm
2
, 5:0.00001mm
2
Angle system ・・・ 0:1deg, 1:0.1deg, 2:0.01deg
0:OFF, 1:Height, 2:Step, 3:Position, 4:Center position,
5:Width, 6:Thickness, 7:Angle, 8:R measurement, 9:Area,
10:Master comparison (Z), 11:Distance(point-point),
12:Distance(point-line), 13:Heigh (Profile compression
(time axis) on), 14:Position (Profile compression (time axis)
on), 15:Deflection width (Profile compression (time axis)
on), 16:Height (simple 3D), 17:Step (simple 3D),
18:Position (simple 3D), 19:Calculation
Vista de pagina 74
1 2 ... 70 71 72 73 74 75 76 77 78 79 80 ... 93 94

Comentarios a estos manuales

Sin comentarios