55LJ-V7000_COM_RM_E
(ii) For configuration 2
Heads: 2
Measurement range X direction: Full
Binning: on
Wide: off
Compression (X axis): 2
Compression (time axis): On
The amount of profile data is 200
The profile data storage order is as follows. (See profile data storage order for 1)
1. Head A MAX profiles (200)
2. Head A MIN profiles (200)
3. Head B MAX profiles (200)
4. Head B MIN profiles (200)
When getting 10 profiles with LJV7IF_GetProfile, the data below is stored in pdwProfileData.
Profile 1 LJV7IF_PROFILE_HEADER 32bit×6
1. Head A MAX profiles (200)
32bit×800
(800=200×4)
2. Head A MIN profiles (200)
3. Head B MAX profiles (200)
4. Head B MIN profiles (200)
LJV7IF_PROFILE_FOOTER 32bit×1
.
.
.
Profile 10 LJV7IF_PROFILE_HEADER 32bit×6
1. Head A MAX profiles (200)
32bit×800
(800=200×4)
2. Head A MIN profiles (200)
3. Head B MAX profiles (200)
4. Head B MIN profiles (200)
LJV7IF_PROFILE_FOOTER 32bit×1