Chapter 4 Use of Data Processing Functions
4
54
Sampling period
Specify the length of the sampling period after the hold-reset input.
The sampling delay time and sampling period are specified with time length.
The unit of the setting display is "ms".
Example
1000.1 = 1000.1 ms
Note 1: The sampling delay time and sampling period can be specified within the
range of 0.1 to 19999.9 ms.
Note 2: When the measurement type is set to "b-0", settings " [-0", "[-1", "[-22"
and "[-23" cannot be selected.
Setting function "["
1. Press the key for at least 2 seconds.
The sensor enters the common function selection mode.
2. Press the
key to make function "[" flash.
3. Press the
or key to select the function setting mode.
4. Press the
key to select the desired function.
When "[-0" is selected:
5. Press the key.
The sensor saves the setting and returns to the measurement state.
(Time)
Sampling period
Trigger point Starting point
The measured value is displayed/output
at this point.
Sampling
delay time
Vista de pagina 63