Chapter 4 Use of Data Processing Functions
4
50
Simple bottom-dead-center measurement function (Internal trigger) [b-0]
Measures the "minimum value" detected during a specified period.
* The external trigger mode is not available for the simple bottom-dead-center measurement. For the
internal trigger setting, only a trigger level and trigger hysteresis can be specified.
If a comparator output disable input turns ON before the comparator operation,
the comparator output does not turn ON.
The trigger level is factory-adjusted to the full scale.
Turning the strobe output from ON to OFF results in the off-delay of 2 ms for
updating the comparator output.
Limited bottom-dead-center measurement function [b-1]
Measures the "minimum value" detected during a specified period (sampling
period).
For the limited bottom-dead-center measurement function, the sampling period can
be specified with the combination of the trigger mode and delay time settings.
For the details of the trigger mode and delay time, refer to pages 53 to 55.
Timing diagram
External trigger mode
If a comparator output disable input turns ON before the comparator operation,
the comparator output does not turn ON.
The sampling period is between the UP edge of the timing input (hold-reset
input) and the UP edge of the next timing input. The value measured at the
instant when the timing input turns ON is displayed/output.
Reference: To clear the measured value being held and to start the measurement
again, short-circuit the hold-reset and GND terminals.
(t)
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
0
When the power is turned ON or the hold-reset signal is input,
the display shows " " until the first timing signal is input.
Displayed value
POWER ON or
Reset input
Strobe output
HIGH OUT
HI
GO OUT
GO
LOW OUT
LO
Comparator
output disable input
Bottom-dead-center values
Trigger level
(t)
0
ON
OFF
When the power is turned ON or the hold-reset
signal is input, the display shows " " until
the first measured value is determined.
Displayed value
Timing input
Limited bottom-dead-center values
Sampling period Sampling period
Sampling period