Chapter 6 Normal Mode
44
6
99
99
9 Average
The number of averaging measurements can be set based on the application as
follows.
Increase the number of averaging measurements:
To average fluctuations in measured values to obtain stable data
Reduce the number of averaging measurements:
To increase high speed differentiation speed
Setting Procedure
1. Select the OPTIONS screen.
Press the [OPTIONS] button.
2. Select the OUTPUT MODE screen.
Press the [OUTPUT] button.
3. Set the number of averaging measurements.
Press the button corresponding to the output number for which the number of
averaging measurements is to be set.
Press the [AVERAGE] button and set a number of averaging measurements.
OPTIONS
OUTPUT OUT1 • • • OUT4
LASER ON OPTIONS
NOR
MAL
P. 1
DISPLAY
DATA
LIMIT
SETUP
PROGRAMCALIB OPTIONS
AREA
OUTPUT
INSPECT
UTILITY
Select Option to setup.
MODE
CHANGE
Normal
-> Pitch
LASER ON OUTPUT MODE
NOR
MAL
P. 1
OUT1
OUT2
OUT3
I/O SLOT
SETUP
OUT4
ESC
Select Output to set.
OUTPUT MODEOUT1LASER ON P. 1
+A1 OFF OFF OFF
AREA1 AREA2 AREA3 AREA4
100
AVERAGE
CAL-
CULATE
1 (0.833ms)
MEASUR-
ING MODE
SELF-TIMING
INTERVAL (ms)
NORMAL
DIGIT
SUPPRESS
NONE
ESCHELP NEXT
NOR
MAL