Keyence FS-N10 Series Manual de usuario Pagina 92

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 116
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 91
5
Specifications
5-6
- Digital Fiber Sensor FS-N10 Series User's Manual -
5-2
Input/Output Circuit Diagram
1-Output Type
FS-N11N / N12N FS-N11P / N12P
FS-N11CN/N12CN/N11EN/N12EN FS-N11CP / N12CP
0 V
12 to 24 VDC
Brown
*1
Sensor main circuit
Black
Load
Blue
*1
(Control output)
*1 FS-N11N only
Overcurrent
protection circuit
Brown
*
Blue
*
Black
0 V
12 to 24 VDC
* FS-N11P only
Sensor main circuit
Load
Overcurrent
protection circuit
(Control output)
12 to 24VDC
DC3.3V
(4)
(Control output)
PLC, etc.
Short-circuit current
1 mA or less
(2)
(1)
*1
(3)
*1
0V
Sensor main circuit
Overcurrent protection circuit
Load
*1 FS-N11CN/N11EN only
12 to 24VDC
(4)
(Control output)
PLC, etc.
Short-circuit current
2 mA or less
(2)
(1)
*1
(3)
*1
0V
Sensor main circuit
Overcurrent protection circuit
Load
*1 FS-N11CP only
1
2
3
4
M8 connector Pin layout
e-CON connector Pin layout
1
2
3
4
2-Output Type
FS-N13N/N14N FS-N13P / N14P
12 to 24VDC
DC3.3V
Black
(Control output 1)
PLC, etc.
Short-circuit current
1 mA or less
White
(Control output 2)
Pink
Brown
*1
Blue
*1
0V
Sensor main circuit
Overcurrent protection circuit
Load
Load
*1 FS-N13N only
12 to 24VDC
Black
(
Control output 1)
PLC, etc.
Short-circuit current
2 mA or less
White
(Control
output 2)
Pink
Brown
*1
Blue
*1
0V
Sensor main circuit
Overcurrent protection circuit
Load
Load
*1 FS-N13P only