4-3 Detection Settings (Func)
4
Settings for Advanced Functions
4-22
- Digital Fiber Sensor FS-N10 Series User's Manual -
The analog output can be automatically scaled so that the 5 V is output in respect to
the received light intensity "100.0". This function is used simultaneously with the
various preset function. This function is useful when frequently using the preset
function as the analog output can be constantly sequenced with the ".0 to 100.0"
display, etc.
* Not available for the FS-N10 Series shipped before March 10, 2011.
1
When received light intensity is dis-
played, press and hold the [MODE] but-
ton, [SET] and button
simultaneously for 3 seconds or more.
ProG YES or ProG no is displayed.
2
Press the [MODE] button once.
3
Using the button, select Pr-A Std
to not change the analog upper limit
value when the preset function is exe-
cuted, and select Pr-A PrSt to change
the analog upper limit value sequen-
tially when the preset function is exe-
cuted. Then, hold down the [MODE] button.
When "Std" (default) is set, the analog output upper limit will not change
even if the various preset function is used.
Analog scaling mode (FS-N11MN only)