6-5 Index
6-15
- Digital Fiber Sensor FS-N10 Series User's Manual -
6
Appendix
2-output Settings ( )
*12
…(page 4-35)
*1 You can press the button to set between the range of -99P and 99P.
*2 Press the button to set between the range of 1 and 9999 (ms).
*3 Press the button to set the adjustment sensitivity to a range of between LEu1 and LEu3 and set the warning output level to a range of
between 0P and 100P.
*4 Press the button to switch between oFF/on/KEEP.
*5 Pressing the button enables you to set to the range within 1 to100.
*6 The analog output upper limit can be set between 50 and 65535.
*7 FS-N11
C/N12C/N11EN/N13/N14 only
*8 Moni
tor output type only (FS-N11MN Only).
*9 Press the button to toggle between Std/P~P_/b~b_/P_b~/P~b_.
*10 Press the button to set between the range of 100P and 200P.
*11 Main unit only.
*12 Only 2-output types (FS-N13 / N14).
*13 Press the button to select the User (user reset) or Auto (auto reset) resetting methods.
Press the button and the button simultaneously to return to the
previous setting option.
When the button is held down, the settings menu will end and the received light
intensity setting screen will appear.
Light intensity detection mode
Limit setting output mode *
13
Warning output mode
Timer OFF
Off-delay timer *
2
On-delay timer *
2
One-shot timer *
2
Settings complete
Return to normal display
…(page 4-38)
…(page 4-36)
…(page 4-37)
…(page 4-38)
…(page 4-38)
…(page 4-38)
…(page 4-38)
MODE
MODE
MODE
MODE
MODE
MODE
MODE
Reference
MODE
MODE
List of settings