4-3 Detection Settings (Func)
4
Settings for Advanced Functions
4-10
- Digital Fiber Sensor FS-N10 Series User's Manual -
When the received light intensity stays lower than a given warning
level, the received light intensity correction stops and the DTM
indicator flashes.
"Changing the warning output level" (page 4-13)
The light intensity correction stops if the raw received light inten-
sity drops below 50 (200 when the light intensity expansion setting
is set to FuLL). The raw received light intensity can be confirmed by
pressing the [MODE] button for longer than 3 seconds on the Basic
screen.
"Display Gain" (page 4-32)
By pressing the [PRESET] button,
the current value (received light
intensity) can be forcibly calibrated
to "100.0". Calibration is completed
when the current value stops flash-
ing. (At this time, the setting value is internally calibrated so that the
received light intensity and setting value ratio stay constant.)
•You can also set the interval for executing correction, and/or the level of
received light intensity change for issuing a warning.
"Adjusting the correction interval" (page 4-12)
"Changing the warning output level" (page 4-13)
•The saturation level is fixed to 101P (101%). To display a value higher
than 100.0, turn the preset saturation function OFF.
"Preset Saturation Function" (page 4-28)
Point