Settings for Advanced Functions
4-7
- Digital Fiber Sensor FS-N10 Series User's Manual -
4-3
Detection Settings (Func)
There are 3 types of timers available.
* Example of the light-ON (L-on) mode for the reflective model and the dark-ON (d-
on) mode for the thrubeam/retro-reflective
When using the 2-output type, different timer functions and timer times
can be set separately for channels 1 and 2.
"Output Timer for Output2" (page 4-38)
The timer can only control on/off switching of the sensor output.
Output Timer
Refer to page 4-2 "Detection Settings (Func)" for setting methods.
Display Function
Timing chart
*
toFF Uses no output timer. (Default)
oFFd
Off-delay timer
Turns off the output at a specified
time after the detection signal
goes off.
Setting range: 1 to 9999 ms
Default: 10 ms
on-d
On-delay timer
Turns on the output at a specified
time after the detection signal
goes on. Useful if the ON duration
is limited because the workpiece
is shaky such as by vibration.
Setting range: 1 to 9999 ms
Default: 10 ms
Shot
One-shot timer
Turns on the output and keeps it
on for a specified period after the
detection signal goes on.
Setting range: 1 to 9999 ms
Default: 10 ms
OFF
ON
With workpiece Without workpieceWithout workpiece
Control output
Timer-set period
OFF
ON
With workpiece Without workpieceWithout workpiece
Control output
Timer-set period
OFF
ON
With workpiece Without workpieceWithout workpiece
Control output
Timer-set period
OFF
ON
With workpiece Without workpieceWithout workpiece
Control output
Reference