3-4 Message Communication
3-35
3
Communicating with FD-MH Series
- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (FD-MH) -
For details on current value 0 and current value 1, refer to "Current
Value 0/Current Value 1" (Page 3-12).
00H
99H
(153)
Current
Value 0
(ID10)
Indicates the current value 0 of the sensor of ID
number 10.
Parameter range:
-2147483648 to 2147483647 (initial value: 0)
R
WORD
9AH
(154)
to 9EH
(158)
Current
Value 0 (ID
Number 11)
to (ID
Number 15)
(Unassigned)
RDINT
9FH
(159)
Reserved for system
A0H
(160)
to AEH
(174)
Current
Value 1 (ID
Number 1) to
(ID Number
15)
(Unassigned)
RDINT
AFH
(175)
Reserved for system
B0H
(176)
Sensor
Status Mask
Setting
Set up the condition to determine if the sensor
error or warning is a recoverable DL-EP1 error
(MS LED blinks in red). If mask is selected, MS
LED does not blink in red when a sensor error or
warning occurs.
Parameter range: 0 to 1 (initial value: 0)
0: Not mask
1: Mask
R/W UINT
B1H
(177)
Sensor
Connected
Number
Indicates the number of connected sensor
amplifiers.
Parameter range: 0 to 10 (initial value: 0)
RUINT
B2H
(178)
to C7H
(199)
Reserved for system
0300H
(768)
Error Code
(ID number
00)
Indicates the error code of ID number 0.
Parameter range: 0 to 65535 (initial value: 0)
RUINT
0301H
(769) to
0309H
(777)
:
030AH
(778)
Error Code
(ID number
10)
Indicates the error code of ID number 10.
Parameter range: 0 to 65535 (initial value: 0)
RUINT
030BH
(779) to
030FH
(783)
Error Code
(ID number
11) to (ID
number 15)
(Unassigned)
0310H
(784) to
04FFH
(1279)
Reserved for system
Instance
ID
Attribute
ID
Name Description
Attribute
Data
Ty p e
Reference