Keyence DL-PN1 Manual de usuario

Busca en linea o descarga Manual de usuario para Sensores Keyence DL-PN1. KEYENCE DL-PN1 User Manual Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - DL-PN1 (IB)

427GBPROFINET Communication UnitDL-PN1 (IB)User's Manual Read this manual before use.Keep this manual in a safe place for future reference.

Pagina 2 - Introduction

8- PROFINET Communication Unit DL-PN1 User's Manual (IB) -Reading an output from a sensor amplifierAvailable outputs: High, Low, GoThis example

Pagina 3 - Overview of PROFINET

9- PROFINET Communication Unit DL-PN1 User's Manual (IB) -Reading comparator values (P.V. values) from sensor amplifiersThis example shows how to

Pagina 4 - I/O Controller

10- PROFINET Communication Unit DL-PN1 User's Manual (IB) -Record Data Communication What is record data communication?Record data communicati

Pagina 5 -  For panel mounting type

11- PROFINET Communication Unit DL-PN1 User's Manual (IB) -PointTo input the ID number for the DL-PN1 into ID, refer to the instruction manual fo

Pagina 6 - Data I/O Communication

12- PROFINET Communication Unit DL-PN1 User's Manual (IB) -64 Error stateWhen the sensor amplifier is in the error state, the corresponding bit

Pagina 7 -  DL-PN1 (Slot 0)

13- PROFINET Communication Unit DL-PN1 User's Manual (IB) -961st Sensor Head 1 IdentificationStores the type of the slot number 01 sensor head (l

Pagina 8

14- PROFINET Communication Unit DL-PN1 User's Manual (IB) -*1 Functions assigned to the external input request 1 to 4 are as follows:• External

Pagina 9 -  Communication Methods

15- PROFINET Communication Unit DL-PN1 User's Manual (IB) -10Reference light registration requestDINT C11 Adjust request DINT C12 Adjust reset re

Pagina 10

16- PROFINET Communication Unit DL-PN1 User's Manual (IB) -39Peak-hold value in hold mode*4*5*7DINT R -999.99 to +999.9940Bottom-hold value in

Pagina 11

17- PROFINET Communication Unit DL-PN1 User's Manual (IB) -64 Group2 Entry count DINT R 1265 HIGH setting value (BANK 0) *7 DINT R/W +20.00 -999.

Pagina 12 - Record Data Communication

IntroductionThis manual describes the basic operations and hardware functions of the DL-PN1.Read the manual carefully to ensure safe performance and f

Pagina 13 -  Access Address (Slot 0)

18- PROFINET Communication Unit DL-PN1 User's Manual (IB) -130 Measurement mode DINT R/W 00: Percent mode1: Dimension mode131 Received/Blocked

Pagina 14

19- PROFINET Communication Unit DL-PN1 User's Manual (IB) -146External input 1 function selection*18 DINT R/W 00: Zero shift input1: Bank A input

Pagina 15

20- PROFINET Communication Unit DL-PN1 User's Manual (IB) -*1 The error content of the sensor amplifier can be checked by noting the ON/OFF sta

Pagina 16

21- PROFINET Communication Unit DL-PN1 User's Manual (IB) -*3 If the judgment value is correct, the parameter range isfrom - 999.97 to +999.98 (p

Pagina 17

22- PROFINET Communication Unit DL-PN1 User's Manual (IB) -*10 The result of the "initial reset request" motion command is included i

Pagina 18

23- PROFINET Communication Unit DL-PN1 User's Manual (IB) -*13 This command reads the execution result of the "tolerance tuning request"

Pagina 19

- PROFINET Communication Unit DL-PN1 User's Manual (IB) -24AppendixSpecificationsThe specifications of the DL-PN1 are as follows:Product name PRO

Pagina 20

25- PROFINET Communication Unit DL-PN1 User's Manual (IB) -Dimensions25.635.443.594.538.1(42.5 )29.4(Unit : mm)

Pagina 21

26- PROFINET Communication Unit DL-PN1 User's Manual (IB) -Data Processing TimeThe data update time for data I/O communication is shown below.

Pagina 22

27- PROFINET Communication Unit DL-PN1 User's Manual (IB) -TroubleshootingThe indicator LEDs on the DL-PN1 can be used to determine the causes of

Pagina 23

1Overview of PROFINETWhat is PROFINET?PROFINET is an open industrial networking standard developed and maintained by the PI (PROFINET International).

Pagina 24 - Bit 3, 2, 1: 1 to 5 V

28- PROFINET Communication Unit DL-PN1 User's Manual (IB) - Bus Failure indicator (BF)This indicator indicates whether the DL-PN1 is communica

Pagina 25 - Reference

29- PROFINET Communication Unit DL-PN1 User's Manual (IB) -Types of error and error code Error code listThe following error codes may occur in t

Pagina 26 - Appendix

30- PROFINET Communication Unit DL-PN1 User's Manual (IB) -Reference programsThis section introduces reference programs for carrying out PROFIN

Pagina 27 - Dimensions

31- PROFINET Communication Unit DL-PN1 User's Manual (IB) -Rewrite the HI setting value Explanation of the program Network1M6.0 (Address 6, Bit

Pagina 28 - Sensor amplifier

32- PROFINET Communication Unit DL-PN1 User's Manual (IB) - Network3If the READ command send processing is successful, M9.1 (Address 9, Bit 1)

Pagina 29 - Troubleshooting

WARRANTIES AND DISCLAIMERS(1) KEYENCE warrants the Products to be free of defects in materials and workmanship for a period of one (1) year from the d

Pagina 30 -  Bus Failure indicator (BF)

Copyright (c) 2014 KEYENCE CORPORATION. All rights reserved.427GB 1104-1 427GB Printed in Japan

Pagina 31 - Types of error and error code

2- PROFINET Communication Unit DL-PN1 User's Manual (IB) -Specifying the IP address using the DCP protocolIn the PROFINET communication, you ca

Pagina 32 - Input PRESET

3- PROFINET Communication Unit DL-PN1 User's Manual (IB) -Communicating with the IB SeriesTypes and Number of Connectable Sensor AmplifiersThe DL

Pagina 33 - Rewrite the HI setting value

4- PROFINET Communication Unit DL-PN1 User's Manual (IB) -DL-PN1 PROFINET Communication OverviewThe DL-PN1 enables you to read or write various

Pagina 34

5- PROFINET Communication Unit DL-PN1 User's Manual (IB) - Data I/O communication device map (DL-PN1  PROFINET I/O controller) DL-PN1 (Slot 0)

Pagina 35 - WARRANTIES AND DISCLAIMERS

6- PROFINET Communication Unit DL-PN1 User's Manual (IB) -* "a" represents a Slot number. When Addresses were assigned in order, the

Pagina 36

7- PROFINET Communication Unit DL-PN1 User's Manual (IB) -*1 External input request to the sensor amplifiers connected to the DL-PN1 (Slot 0) can

Comentarios a estos manuales