- EtherNet/IP Compatible Network Unit DL-EP1 User’s Manual (FD-MH) -
3-4 Message Communication
3-24
3
Communicating with FD-MH Series
(5) Reading the number of decimal places from a sensor amplifier
Message communication reads the number of decimal places of settings read
from the sensor amplifier.
"(5) Reading the number of decimal places in the parameter from a sensor
amplifier" (Page 3-48)
For the FD-MH Series, if the current value is 12.53 l/min, data is stored as
follows:
Data: 1253
Number of decimal places: 2
Perform calculation from the read data and the number of decimal places.
FD-MH
Command
Response
DL-EP1Scanner
<Details of command>
Service code: 4CH
Class ID: 67H
Instance ID: 01H
Attribute ID: 0325H(805)
Reads the number of decimal places of the
FD-MH current values (instantaneous flow rate)
Reference
125312.5312.53 l/min
Number of
decimal places
21