
2.4 Instruction Details
3-86
2
Chapter 2 Instructions
HSP: High Speed
Shortens time constant of specified input
relay to 10 µs to increase input response.
SET
1
AND
8
FUN
HSP
nnnn
0000
HSP
0001
0001
0500
SET
0002
0501
SET
0003
0500
RES
0501
RES
Example
Coding
Timing diagram
Description
• When enable input 0000 turns ON, the time constant of input 0001 (specified by
HSP) changes from 10 ms to 10 µs.
• When enable input relay 0000 is ON and the scan time is 1 ms, and when the
ON time ( ) of input relays 0001 and 0002 is 5 ms, output relay 0500 turns ON
but 0502 does not.
➮
"1.4.3 Constant Scan Time Mode" (p. 3-25)
Note 1: The time constant is switched by special utility relays 2609 through 2612
with the expansion units, or by the provided switches with I/O distribution module.
Note 2: The HSP instruction is used for the input to basic units only.
Enable input
Line No. Instruction Operand
0000 LD 0000
0001 HSP 0001
0002 LD 0001
0003 SET 0500
0004 LD 0002
0005 SET 0501
0006 LD 0003
0007 RES 0500
0008 RES 0501
ON ON ON
ON
0000
0002
0001
0003
0500
0501
ON ON
ONON
ON ON
ON
OFF
ON
5 ms 5 ms 15 ms
:
HSP
KVNKA Chap 02_4aP.p65 08.3.11, 11:58 AM86
Comentarios a estos manuales