Keyence IB Series Manual de usuario Pagina 84

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 124
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 83
4-2 Basic Settings and Advanced Settings
4-32
4
Setting Various Functions
IB-E
When Peak hold, Bottom hold or Peak-to-Peak hold is set
" 6. Timing Input" (page 4-23) setting: "Level"
" 6. Timing Input" (page 4-23) setting: "Edge"
Minimum input time
ON time: 0.5 ms
OFF time: 0.5 ms
When Auto peak hold or Auto bottom hold is set
Minimum input time
ON time: 0.5 ms
OFF time: 0.5 ms
Judgment value (P.V.)
judgment output
Max. 0.5 ms
Max. 0.5 ms
Min. 0.5 msMin. 0.5 ms
ON
OFF
Timing input
Max. 0.5 ms
Sampling period 1
Sampling period 1 result
Sampling period 2 result
Previous result
Sampling period
2
Judgment value (P.V.)
judgment output
Max. 0.5 ms
Max. 0.5 ms
Min. 0.5 msMin. 0.5 ms
ON
OFF
Timing input
Sampling period 1
Sampling period 1 result
Sampling period 2 result
Previous result
Sampling period 2 Sampling period 3
Max. 0.5 ms
Max. 0.5 ms
Max. 0.5 ms
Min. 0.5 msMin. 0.5 ms
ON
OFF
Timing input
Sampling is not started in this period
Sampling is started in this period
Vista de pagina 83
1 2 ... 79 80 81 82 83 84 85 86 87 88 89 ... 123 124

Comentarios a estos manuales

Sin comentarios