2-1 Mounting and Wiring the Sensor Amplifier Unit
2-7
IB-E
2
Installation and Connection
Power/Input-output cable
"Output Circuit" (page 5-4)
*1 IB-1050/IB-1550 (expansion units) do not have brown, blue or light blue wires. Power
is supplied to the expansion units through IB-1000/IB-1500 (main unit).
*2 The analog output can be set to any of the following options either “when the power is
turned on for the first time” or “when performing the initial reset”.
Not used (OFF)
•0 to 5 V
-5 to 5 V
•1 to 5 V
4 to 20 mA
"3-1 Operation when the Power is Turned On for the First Time" (page 3-2)
"3-5 Initial Reset (Initialize)" (page 3-12)
*3 The external input can be selected among the following in addition to the above.
Bank A input
Bank B input
Laser emission stop input
Not used (OFF)
Adjust input can be selected only for the external input 4.
"10. External Input" (page 4-29)
Brown
Blue
Black
White
Gray
Light blue
Orange
Shield
Pink
Yellow
Pink/Purple
Purple
Green
10 to 30 VDC
0 V
HIGH judgment output
LOW judgment output
GO judgment output
Analog output +
Analog output GND
External input 1 (Zero shift input)
External input 2 (Reset input)
External input 3 (Timing input)
External input 4 (Not used)
Check output
*1
*1
*1
*2
*2
*3
*3
*3
*3