LK-Navigator 2 96134EConfiguration Software LK-H2 for the LK-G5000 SeriesRead this manual before use. Keep this manual in a safe place for future
1-411 Before Use
1-511 Before UseData storageThe controller has a data storage function for storing measurement values. The PC can be used to control these functions:
1-611 Before UseOperating environmentThe following environment is required to run LK-Navigator 2. Check that the PC meets the following conditions, a
2-1 22 Connecting the Controller and PC... 2-2Installing the Software ...
2-222 Preparations before OperatingConnecting the Controller and PCThis section explains how to connect the controller and the PC. The controller pro
2-322 Preparations before OperatingEthernet connectionThis section explains how to connect the controller and PC using an Ethernet connection. An Eth
2-422 Preparations before OperatingChange the communication settingsWhen connecting via Ethernet, the communication settings for connecting to the ne
2-522 Preparations before OperatingRS-232C connectionThis section explains how to connect the controller and PC with an RS-232C cable. To use the RS
2-622 Preparations before OperatingInstalling the SoftwareThis section explains the procedures for installing LK-Navigator 2 and the USB driver on yo
2-722 Preparations before OperatingUninstallationThis section explains the procedures for uninstalling LK-Navigator 2 from your PC. • This procedure
2 IntroductionThis manual explains the installation, handling, operation, and precautions for <<LK-Navigator 2>>. In order to use the fun
2-822 Preparations before OperatingInstalling the USB DriverThis procedure is not required for Windows 7, Vista, XP, or 2000 because the installer in
2-922 Preparations before OperatingLaunching/Exiting LK-Navigator 2This section explains how to launch and exit LK-Navigator 2.Launching• Multiple i
2-1022 Preparations before OperatingRefer to the following explanations before selecting the other options.• "Read from file": Refer to &qu
2-1122 Preparations before OperatingExiting1Click "Exit" at the bottom right of the main window.If any settings were changed, a confirmatio
2-1222 Preparations before Operating
3-1 3Names and Functions... 3-2 Flow of Operation ...
3-233 Window Functions and OperationNames and FunctionsThis section explains the names and functions of the LK-Navigator 2 main window.(1) Menu barDi
3-333 Window Functions and Operation(7) ExitExits LK-Navigator 2 (page 2-9).(8) Open/SaveLoads and saves settings made in LK-Navigator 2. Refer to &q
3-433 Window Functions and OperationFlow of OperationThis explanation will outline the procedures to set the input for HEAD01 to OUT01 after launchin
3-533 Window Functions and OperationBasic SettingsThis section explains the basic settings for the LK-Navigator 2.Head settingsThis section explains
3Safety PrecautionsThis <<LK-Navigator 2>> manual, and the User's manual provide important information on the safe and correct use of
3-633 Window Functions and Operation(3) Basic pointIf several peaks exist when using the transparent object mode, this control specifies whether to u
3-733 Window Functions and Operation Executing ABLE tuning1Click "ABLE Tuning".The "ABLE Tuning" dialog appears.• If you do not
3-833 Window Functions and OperationAlarm error(1) Number of ErrorsSets the number of cycles to hold the most recent valid measurement (Setting range
3-933 Window Functions and OperationOUT settingsThis section explains the items and functions on the "OUT Settings" tab.These settings def
3-1033 Window Functions and OperationAVE/P-P/MAX/MINSets the type of output to associate with the OUT to configure.The operation specified from the &
3-1133 Window Functions and OperationMeasurement, Tolerance(1) MeasurementSets the measurement and tolerance comparator method.Measurement typeSets t
3-1233 Window Functions and Operation(2) FilterTypeSets the filtering process to apply to the measurement.Averaging TimesSets the number of averaging
3-1333 Window Functions and OperationScaling, Offset(1) Scaling SettingSets the scaling.Input1/ Display1, Input2/ Display2Sets how to display the inp
3-1433 Window Functions and Operation Setting scaling from measurement data1Click "Set from the Measurement data".A confirmation dialog ap
3-1533 Window Functions and OperationDisplay, Analog(1) DisplayMinimum display unitSets the decimal point position and number of digits to display fo
4 End-user License AgreementUse of <<LK-Navigator 2>> (the "software") is conditional upon the customer's acceptance of th
3-1633 Window Functions and OperationCommon settingsThis section explains the items and functions on the "Common Settings" tab.Click the &q
3-1733 Window Functions and Operation(5) Copy common settings/ Paste common settingsUse this button to copy these settings to the common settings in
3-1833 Window Functions and OperationSynchronization setting(1) Synchronization settingCheck the OUTs to synchronize.If the storage cycle (page 3-37)
3-1933 Window Functions and OperationMutual interference prevention(1) Mutual interference preventionUse this setting to prevent interference when mu
3-2033 Window Functions and OperationData storage(1) Amount of Data StoredSets the number of data points to store.(2) Storage cycleSets the interval
3-2133 Window Functions and OperationAnalog output(1) Analog outputSets an analog channel from CH01 to CH12 to each OUT to be used as an analog outpu
3-2233 Window Functions and OperationSettings listThis tab provides a view of the items set within a program. Click the "Settings List" tab
3-2333 Window Functions and OperationDownloading, uploading settingsThis section explains how to download and upload settings from the controller.•
3-2433 Window Functions and OperationEnvironment SettingsThis section explains how to configure the operating environment of the controller.Click the
3-2533 Window Functions and Operation(2) EthernetIP AddressSets the controller's IP address.Subnet maskSets the subnet mask for the controller.
56. SupportIn accordance with this agreement, the owner shall provide technical support for regarding questions the customer may have regarding this s
3-2633 Window Functions and OperationCommunication SettingsThis section explains how to configure the communications between the controller and PC.Fr
3-2733 Window Functions and OperationProgram SettingsThis section explains the procedures for copying and initializing programs registered in the con
3-2833 Window Functions and OperationInitializing programsThe settings can be initialized to their factory default settings. Initializing erases any
3-2933 Window Functions and OperationMeasurement Value DisplayThis section explains the "Measurement Valu e Display" function that allows
3-3033 Window Functions and Operation(2) Display the measurement data after applying simultaneous auto zero, simul-taneous reset, or simultaneous tim
3-3133 Window Functions and OperationReceived Light Waveform DisplayThis section explains the "View Received Light Waveform" function that
3-3233 Window Functions and Operation(3) Model displayIndicates the model of the head used to acquire the displayed waveform.(4) Waveform display man
3-3333 Window Functions and OperationData Storage SettingThis section explains how to change data storage settings, and about the "Data storage
3-3433 Window Functions and Operation(1) Start StorageStarts storing data on the controller.(2) Stop StorageStops storing data on the controller.(3)
3-3533 Window Functions and OperationHide cursor Hides the cursor.Select cursor Selects and displays the cursor.(8) Waveform nameSets a user-defined
6 ContentsIntroduction ... 2Safety Precautions ... 3End-user License Agreem
3-3633 Window Functions and OperationData storage setting flow1Click "Data Storage Setting".Preset the target OUT, amount of data store, an
3-3733 Window Functions and OperationChanging data s torage settingsAt the "Data Storage" window, click "Data Storage Setting" to
3-3833 Window Functions and OperationLoading storage dataAt the "Data Storage" window, click "Storage Data Readout" to display th
3-3933 Window Functions and OperationLoading/Saving the Settings FileThis section explains how to load and save settings on the PC.Loading the setti
3-4033 Window Functions and OperationChanging "No. of used heads" and "No. of used OUT" in the settings file (LK-Backup) LK-Backu
A-1 Error Messages and Corrective Action... A-2Index...
A-2 AError Messages and Corrective ActionThis section lists the error messages displayed by LK-Navigator 2 when an error occurs, and applicable corre
A-3ADuring configuration Head settings OUT settingsError message Cause CorrectionABLE tuningSetting range is 1 to 99. The ABLE field contains a blan
A-4 A* Figures between () will change depending on the value in the "Minimum display unit" setting. Common settingsSet so the lower limit
A-5AIndexAABLE ... 3-6ABLE tuning ...3-6, 3-7Alarm handling...
1-1 11 Overview of LK-Navigator 2... 1-2Before Use1
A-6AOOffset ...3-13OUT settings...3-9OUT to store ...
Revision HistoryDate of printing Version Revision detailsJanuary 2011 Official release
WARRANTIES AND DISCLAIMERS(1) KEYENCE warrants the Products to be free of defects in materials and workmanship for a period of one (1) year from the d
Copyright (c) 2011 KEYENCE CORPORATION. All rights reserved.130073E 1011-1 96134E Printed in Japan*96134E-1*
1-211 Before UseOverview of LK-Navigator 2LK-Navigator 2 is software for configuring parameters and monitoring the LK-G5000 series controller. It is
1-311 Before UseMonitoring functionsThese two items can be monitored. • Measurement value• Received light waveformThe screen shown below is a display