3-8 Bank Function (Registering Multiple Tolerance Setting Values)
3-22
3
Basic Operations
IB-E
Switching the bank by the external input
When the bank A input and bank B input are set to the external inputs, the bank can be
switched using the external inputs.
"10. External Input" (page 4-29)
The banks are switched with the ON/OFF combination of the bank A input and bank B
input.
The bank input must be held 20 ms or longer.
"10. External Input" (page 4-29)
The combinations of bank A input and bank B input are shown in the following table.
Bank Bank A input Bank B input
Bank 0
OFF OFF
Bank 1
ON OFF
Bank 2
OFF ON
ON: Short-circuited
Bank 3
ON ON
OFF:Open
Reference
If the external input is not set to bank A or bank B, it is regarded as OFF.
Example: If only Bank A input is set for the external input, only two patterns
(bank 0 and bank 1) can be switched using the external input.