Detection mode and setting value
The GP-M Series has two types of detection modes which are
described below.
When the selected function of output 2 is
QWV
(control output), the
output 1 and output 2 can be set separately.
Hysteresis mode (
*PQ
/
*P%
)
Considering
5RT2
= hysteresis, it is the mode for changing the
setting value when ON and when OFF.
• When the output is OFF (right
diagram 1), and the measured
value becomes more
52
than it
will turn on (right diagram 2).
• When the output is ON, and the
measuring value becomes less
than
T2
, it will turn OFF (right
diagram 3).
Window mode (
(PQ
/
(P%
)
This mode determines whether the measured value is within or
outside the area of
(*
to
(.
.
• If the detection value of the
output OFF condition in the right
diagram 1 is more than (
(.
+
*;5
) or less than
(*
, it will turn
ON (right diagram2).
• From that condition the measured
value is larger than
(*
(right
diagram 3), or, less than
(.
, the
right diagram will be OFF.
• If the measured value of the
condition in the diagram on the
right is less than (
(*
-
*;5
) or
more than
(.
, it will be ON.
Explanation of All Functions
*P%
*PQ
Hysteresis
T2
52
(1) (2) (3)
(P%
(PQ
(.
*;5
*;5
(*
(4) (5)
(1) (2) (3)