3-4 Command Parameter List
3-27
3
Communicating with the FD-S series
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (FD-S) -
00
nn25
Instantaneous flow
rate value
*3 R
FD-SS02
-
-400.0 to +400.0
FD-SF1(S) -2000 to +2000
FD-SF1(F) -400.0 to +400.0
FD-SS2(S) -4000 to +4000
FD-SS2(F) -400.0 to +400.0
FD-SF8(S) -16.00 to +16.00
FD-SF8(F) -4000 to +4000
FD-SS20(S) -40.00 to +40.00
FD-SS20(F) -4000 to +4000
nn26
Integrated flow
quantity (for
Version A)
*4 R
FD-SS02
-
-21474836.48 to +21474836.47
FD-SF1(S) -214748364.8 to +214748364.7
FD-SF1(F) -21474836.48 to +21474836.47
FD-SS2(S) -214748364.8 to +214748364.7
FD-SS2(F) -21474836.48 to +21474836.47
FD-SF8(S) -2147483.648 to +2147483.647
FD-SF8(F) -214748364.8 to +214748364.7
FD-SS20(S) -2147483.648 to +2147483.647
FD-SS20(F) -214748364.8 to +214748364.7
nn27
Instantaneous flow
rate (peak hold
value)
*3 R
FD-SS02
-
-400.0 to +400.0
FD-SF1(S) -2000 to +2000
FD-SF1(F) -400.0 to +400.0
FD-SS2(S) -4000 to +4000
FD-SS2(F) -400.0 to +400.0
FD-SF8(S) -16.00 to +16.00
FD-SF8(F) -4000 to +4000
FD-SS20(S) -40.00 to +40.00
FD-SS20(F) -4000 to +4000
nn28
Instantaneous flow
rate (b ottom hold
value)
*3 R
FD-SS02
-
-400.0 to +400.0
FD-SF1(S) -2000 to +2000
FD-SF1(F) -400.0 to +400.0
FD-SS2(S) -4000 to +4000
FD-SS2(F) -400.0 to +400.0
FD-SF8(S) -16.00 to +16.00
FD-SF8(F) -4000 to +4000
FD-SS20(S) -40.00 to +40.00
FD-SS20(F) -4000 to +4000
nn29 to
nn2A
System reserved
nn2B
Bank switching
state
R- -
0: Bank A
1: Bank B
nn2C System reserved
nn2D
Current
temperature
*5 R - - +000.0 to +099.9
nn2E
Te m pe rature
(peak hold value)
*5 R - - +000.0 to +099.9
nn2F
Te m pe rature
(bottom hold
value)
*5 R - - +000.0 to +099.9
nn30
Instantaneous
density
R - - 00.00 to 99.99
Data
category
(HEX)
Data
number
(HEX)
Name
Description Attribute Sensor head
Default
value
Parameter range