7-21
Chapter 7 RS-232C
7
Reading Environment Settings
It is possible to read all environment settings in detail.
Note: P-COPY, P-CLEAR, or L-INSPCT settings are not read with this command.
S A cr
LS
Command
Response
Binary data
S A ,
Data 0 Data 1 Data X
Checksum range
Data 0 through data X (X=87)
The checksum need not be calculated for
simple upload and download
operations.
Checksum Checksum
Writing Environment Settings
Saved environment settings that were read with the read command (SA command) can
be written to the LS-7000 Series.
Note: P-COPY, P-CLEAR, or L-INSPCT settings are not read with this command.
Binary data
S B ,
Data 0 Data 1 Data X
S B cr
LS
Command
Response
Checksum range
Data 0 through data X (X=87)
The checksum need not be calculated for
simple upload and download
operations.
Checksum Checksum
Timing Chart
The following timing chart is for commands and responses.
Command
Command
Response
t
Response
Period t varies with the command as shown below.
Measurement
control
command
t=Sampling period + 3 ms
(2) Program number selection t=9ms
(3) Commands other than (1) or (2) t=3ms
Setting change command t=17ms (40 ms for calibration)
Setting confirmation command t=3ms
Reading and writing whole settings t=35ms
(1) Measured value output under
timing control (Command L)