Keyence LS-7000 Manual de usuario Pagina 156

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 192
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 155
7-14
Chapter 7 RS-232C
7
Area Check
This command makes area check ON/OFF settings and changes the number of edges.
LS
Number of area check edges
OFF : OFF
002~127 : Value specified
with the area
check function
turned ON.
Command
Response
S D
,
A T
,
a
,
f f f cr
S D
,
A T
,
a cr
Area number
1 : AREA 1
2 : AREA 2
Area number
Level
This command changes threshold level settings.
LS
Level
10~99
Command
Response
Area number
1 : AREA 1
2 : AREA 2
Area number
S D
,
L E
,
a
,
g g cr
S D
,
L E
,
a cr
Calculation
This command changes area calculation settings.
LS
Output number
1 : OUT1
2 : OUT2
Command
Response
S D
,
C A
,
h
,
i i cr
S D
,
C A
,
h cr
Calculation coefficient
0 : A1 1 : A2
0 : 0 3 : -1
1 : 1 4 : -0.5
2 : 0.5
Average
This command changes the averaging number
LS
Output number
1 : OUT1
2 : OUT2
Averaging number
00 : 1 03 : 08 06 : 064 09 : 0512 12 : 4096
01 : 2 04 : 16 07 : 128 10 : 1024
02 : 4 05 : 32 08 : 256 11 : 2048
Command
Response
S D
,
A V
,
h
,
j
S D
,
A V
,
h cr
j cr