Chapter 2 Editor
2-39
1
2
1. Select the desired instruction word type from "Instruction Type" located in the
right portion of the window.
Click the desired radio button.
2. Select the desired instruction word from the "Instruction Word" list.
When selecting an instruction word to be executed only once at the ON signal,
click the "Execute Once at ON" check box to add the check mark, and then select
the desired instruction word.
Instruction words and their types
Instruction word type Instruction word
Executed only once at the
ON signal
Basic Instructions LD, LDB, AND, ANB, OR,
ORB, ANL, ORL, OUT. OUB,
SET, RES, TMR, TMH, TMS,
C, UDC, DIFU, DIFD, KEEP,
SFT, HSP, MC, MCR, MEMSW,
END, ENDH
Application Instructions W-ON, W-OFF, W-UE, W-DE,
STG, JMP, ENDS, STP, SET,
ITVL, CTH, CTC, CALL, SBN,
RET, FOR, NEXT, HKEY
Arithmetic Instructions DW, TMIN, LDA, STA, CMP, @TMIN, @LDA, @STA,
ADD, SUB, MUL, DIV, ANDA, @CMP, @ADD, @SUB,
ORA, EORA, SRA, SLA, RRA, @MUL, @DIV, @ANDA,
RLA, COM, INC, DEC, MPX, @ORA, @EORA, @SRA,
DMX, TBCD, TBIN, ASC, @SLA, @RRA, @RLA,
RASC, ROOT @COM, @INC, @DEC,
@MPX, @DMX, @TBCD,
@TBIN, @ASC, @RASC,
@ROOT
Interrupt Instructions DI, EI, INT, RETI
KVSKA Chap 02.P65 08.3.11, 11:28 AM39
Hi