Keyence KV Series Manual de usuario Pagina 115

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 240
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 114
Chapter 3 Simulator
2-91
1
3
Status indication during execution
While a scan or step is executed, the current operation status and the scan time are
displayed in the status indication area on the main window.
Note: While the continuous scan operation is executed, "Execute Scan" is dis-
played. While the continuous step operation is executed, "Execute Step" is dis-
played.
Changing the display size and the display method
Five different sizes are available to display the ladder diagram. The ladder monitor
window can be always displayed below other windows.
When changing the display size
The following five display sizes can be selected.
200% : Displays a ladder diagram at twice the standard size. This size is useful
when characters are small and difficult to read.
150% : Displays a ladder diagram at 1.5 times the standard size.
120% : Displays a ladder diagram at 1.2 times the standard size.
100% (Normal): Displays a ladder diagram in the standard size.
80% : Displays a ladder diagram in the smallest size. This size is useful when
checking the entire operation because the maximum number of cells can be
displayed on the screen.
To set the display mode, perform the following procedure.
Selecting the upper mode: View Zoom In (Ctrl + PageDown)
Selecting the lower mode: View Zoom Out (Ctrl + PageUp)
When displaying the ladder monitor window at the bottom
The ladder monitor window can always be displayed below the mnemonic list
window and other windows. Therefore, each device can be registered to each
monitor by dragging and dropping it even if the registration monitor window and the
monitor all window are placed on top of the ladder monitor window.
To display the ladder monitor window at the bottom of the screen, perform the
following procedure.
To return the display status to the previous setting, repeat the same procedure.
View Move Ladder to Bottom
Step No. being executed
Status (Operating, Stopped or Paused)
Operation mode being executed
Scan time
KVSKA Chap 03.P65 08.3.11, 11:29 AM91
Vista de pagina 114
1 2 ... 110 111 112 113 114 115 116 117 118 119 120 ... 239 240

Comentarios a estos manuales

Hesham 28 Mar 2025 | 18:51:15

Hi