3-3 Explicit Messaging
3-25
3
Communicating with the SK-1000 Series
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (SK-1000) -
• When writing data of DINT type
Response format
• When normal (for writing response data of WORD, UINT, or DINT type)
• When abnormal
The following formats are used to activate the key lock on all sensor amplifiers
connected to the DL-DN1.
Command format
Service data
Destination
node
address
Service
Code
Attribute ID
**h 10h 0067h ****h **h ********h
Class ID
Instance ID
Service data
Data to be written
Specifi es the parameter to
be written.
Responder
node address
Se rv ice Code
0002h **h 90h 0000h
Response data
Number of receiv ed b ytes
Responder
node address
Se rv ice Code
0002h **h 94h FF**h
Response data
(Error code)
Number of receiv ed b ytes
Locking Sensor Amplifiers
Service data Action Description
0000h
Deactivate key lock Deactivates key lock.
0001h
Activate key lock Activates key lock.
Destination
node address
Service
Code
**h 4Ch 0067h 0000h (See below)
Class ID
Instance ID Service data