Keyence DL-DN1 Manual de usuario Pagina 32

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 76
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 31
3-2 I/O Communication
3-6
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (SK-1000) -
3
Communicating with the SK-1000 Series
"3-output + current value" mode
5-output mode
"5-output + current value" mode
3-output + monitor
No extended mode Yes - - -
3-input - Yes Yes Yes
BANK change - - Yes -
Setting value rewrite - - - Yes
Area IN OUT IN OUT IN OUT IN OUT
Number of sensor
amplifiers
114
0
20
6
24
10
28
24
2 18242832
3 22283236
4 26323640
5 30364044
6 34404448
7 38444852
84248 56
52(bytes)
5-output
No extended mode Yes - - -
5-input - Yes Yes Yes
BANK change - - Yes -
Setting value rewrite - - - Yes
Area IN OUT IN OUT IN OUT IN OUT
Number of sensor amplifiers 1-8 12 0 22 10 26 14 34 40
(bytes)
5-output + current
value
No extended mode Yes - - -
5-input - Yes Yes Yes
BANK change - - Yes -
Setting value rewrite - - - Yes
Area IN OUT IN OUT IN OUT IN OUT
Number of sensor
amplifiers
118
0
28
10
32
14
40
40
2 22323644
3 26364048
4 30404452
5 34444856
6 38485260
7 42525664
8 46566068
(bytes)
Vista de pagina 31