3-2 I/O Communication
3-5
3
Communicating with the SK-1000 Series
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (SK-1000) -
Configure the operating mode setting switch to suit the operating mode to be used.
"Configuring the Operating Mode Setting Switch" (page 3-5)
The memory size occupied by the DL-DN1 varies with the selected operating mode
and the number of connected sensor amplifiers.
3-output mode
Configuring the Operating Mode Setting Switch
DIP switch Operating mode
1 2 3 4 Output
Current
value
External
input
BANK
change
Setting value
rewrite
OFF OFF OFF OFF
3-output
No
No
No
No
OFF ON OFF OFF Yes
OFF OFF OFF ONNo
3-input
OFF ON OFF ON Yes
OFF OFF ON OFF No
Yes
OFF ON ON OFF Yes
OFF OFF ON ONNo
NoYes
OFF ON ON ON Yes
ON OFF OFF OFF
5-output
No
No
No
No
ON ON OFF OFF Yes
ON OFF OFF ONNo
5-input
ON ON OFF ON Yes
ON OFF ON OFF No
Yes
ON ON ON OFF Yes
ON OFF ON ONNo
NoYes
ON ON ON ON Yes
Occupied Memory
3-output
No extended mode Yes - - -
3-input - Yes Yes Yes
BANK change - - Yes -
Setting value rewrite - - - Yes
Area IN OUT IN OUT IN OUT IN OUT
Number of sensor amplifiers 1-8 8 0 14 6 18 10 22 24
(bytes)