1
IG-E
Safety Information for IG series
At startup and during operation, be sure to monitor the functions and performance of this
product and confirm normal operation.
We recommend that you take substantial safety measures to avoid any damage in the
event that a problem occurs.
If the product is modified or used in any way other than those described in the
specifications, its functions and performance cannot be guaranteed.
When this product is used in combination with other devices, the functions and
performance may be weaken, depending on the operating conditions, surrounding
environment, etc.
Do not use this product for the purpose of protecting the human body.
Do not subject each device including peripheral devices to rapid temperature change.
Product failure may occur due to condensation.
* The classification is based on IEC60825-1 standard following the Laser Notice No.50
from FDA (CDRH).
Laser emission stop input
When the laser emission stop input is set for the external input, the laser emission stops by
setting the external input to ON (for 2 ms or more). The laser emission continues to stop
while the external input is ON. When the external input is set to OFF, the laser is emitted
within 2 ms.
General Precautions
Safety Precautions on Laser Product
WARNING
This product employs a semiconductor laser for its light
source.
Use of controls or adjustments or performance of proce-
dures other than those specified herein may result in haz-
ardous radiation exposure.
Follow the instructions mentioned in this manual. Other-
wise, injury to the human body (eyes and skin) may
result.
Precautions on class 1 laser products
Do not disassemble this product. Laser emission from
this product is not automatically stopped when it is
disassembled.
Do not stare into the beam.
Sensor Head IG-010/IG-028
Wavelength 660 nm
Output 62 PW
Pluse width 48 Ps
FDA(CDRH)Part1040.10 * Class 1 Laser Product
IEC60825-1 Class 1 Laser Product
96083E