Keyence DL-DN1 Manual de usuario Pagina 78

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 84
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 77
5-3 Troubleshooting
5-6
- DeviceNet Compatible Network Unit DL-DN1 User's Manual -
5
Appendix

Network status indicator (NS)
This lamp indicates whether the DL-DN1 is properly communicating with the
DeviceNet.
LED status Condition Corrective action
Green Solid Communicating properly. -
Flashing The DL-DN1 is connected
to the network, but the com-
munication with the master
unit is not established.
Check that the DL-DN1 is regis-
tered in the master unit.
The DeviceNet cable was
disconnected while in oper-
ation.
Check that the DeviceNet cable
is connected correctly.
Red Solid Network error. Check that the node address of
the DL-DN1 is not duplicated
with that of another slave unit.
Flashing Minor network error. Check that the data link is prop-
erly configured, and then cycle
power.
Green/
red
Flashing The DL-DN1 is checking its
operation in the power-on
process.
After completing the check, the
DL-DN1 automatically switches
to the normal state.
Not lit Not connected to the net-
work.
Check that the DL-DN1 is cor-
rectly connected with the sensor
amplifiers.
Vista de pagina 77
1 2 ... 73 74 75 76 77 78 79 80 81 82 83 84

Comentarios a estos manuales

Sin comentarios