Keyence DL-DN1 Manual de usuario Pagina 23

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 72
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 22
2-2 Wiring
2-7
2
Connection and Configuration
- DeviceNet Compatible Network Unit DL-DN1 Users Manual (FD-MH) -
2
Install a shrinkable tube.
Cover the exposed sheathed conductors and the sheath using a shrinkable
tube approximately 40 mm long.
3
Strip the sheathed conductors.
Strip approximately 10 mm of sheath from the end of each conductor.
If you are using solderless terminals, perform cable wiring/
trimming appropriately to suit the specifications of the partic-
ular terminals.
Recommended solderless terminals: Phoenix Contact's A/AI
Series
Do not perform soldering (pre-soldering) on the trimmed end
of the cable.
Approx. 40mm
Shrinkable tube
Sheath
Approx. 10mm
Sheathed conductor
Point
Vista de pagina 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 71 72

Comentarios a estos manuales

Sin comentarios