
3-4 Command Parameter List
3-35
3
Communicating with the SK-1000 Series
- CC-Link Compatible Network Unit DL-CL1 User’s Manual (SK-1000) -
*17 The external input status is "1" when the external input is ON, and is "0" when
the external input is OFF. Bits 0, 1, 2, and 3 correspond to external inputs 1, 2, 3,
and 4, respectively.
Assume the read data is "06":
Translating "6" to a binary number gives "0110".
*18 Stores the read string in the remote registers in ASCII code.
For "SK-1": RWr03=312Dh, RWr02=4B53h
Reference
0110
External input 4: OFF
External input 3: ON
External input 1: OFF
External input 2: ON
Comentarios a estos manuales