Mounting and Connecting the DL-RB1A
2-1 Connecting the DL-RB1A to External Devices
Precautions when wiring (OP-23139 and OP-42224)
Carefully follow the precautions below when performing wiring.
• Use a single shielded cable.
• Use the following type of compliant cable:
Cable size: AWG24 to 22 (stranded)
Cross-section: 0.2 to 0.3 mm
2
Cable sheath diameter: 1.5 to 1.1
• Cut the end of the cable straight across.
• After performing the wiring, check that the cable is securely held in the clamp and that it is inserted
firmly.
• Cut the cable clearly so that no loose threads remain. (The sheath does not need to be removed.)
• Use the thin cable contacts OP-30594 (200 pieces included) for AWG28 to 26.
(Use this together with OP-23139 or OP-42224.)
Cable size: AWG28 to 26
Cross-section: 0.08 to 0.14 mm
2
Cable sheath diameter: 1.3 to 1.1