Introduction
1
1-1 Before Using the Unit
(2) Sensor amplifier connector (for DIN rail mounting type)
Use this connector to connect DL-RB1A to the sensor amplifier that is mounted on a DIN rail.
(3) Sensor amplifier connector (for panel mounting/large display type)
Use this connector to connect DL-RB1A to a sensor amplifier for panel mounting/large display.
The optional extension cable (OP-35361) must be used for connection.
You cannot connect DL-RB1A simultaneously to a DIN rail mounted sensor amplifier and a
panel mounted sensor amplifier.
(4) Alarm indicator
The alarm indicator is lit during the following conditions.
Immediately after turning on the DL-RB1A
*1
When updating the BCD output, if the selected ID number for the sensor amplifier does not exist
When updating the BCD output, if there is an error with the selected ID number for the sensor
amplifier
When there is overcurrent on one of the outputs (Pin Nos. 6 to 32)
*2
• Until the initialization is completed if the main unit (ID: 00) is initialized while it is connected to the
GT2-100N/100P.
*1 After turning on the power, the alarm indicator lights up for the following amount of time, and BCD
output cannot be performed during this time. (“+EEEEEE” is output during this time.)
*2 The alarm indicator flashes.
(5) Power indicator
Lights up in green while the power is on.
(6) I/O connector
Connector for data input and output.
For information about each signal on the connector, refer to "I/O Connector" (page 15).
Note
No. of connected units Incommunicable time
1 to 5 Approx. 2 s
6 to 10 Approx. 4 s
11 to 15 Approx. 6 s