3-6 DP-V1 Service
3-29
- PROFIBUS DP Compatible Network Unit DL-PD1 User's Manual (GT2) -
Executing Communication
*1 Functions assigned to the external input request 1 to 4 are as follows:
• External input request 1: PRESET input
• External input request 2: TIMING input
• External input request 3: RESET input
• External input request 4: ERROR CLEAR input
Refer to the GT2 series user's manual.
*2 If the judgment value is correct, the parameter range is -199.9999 to +199.9999.
• When the comparator value is over range, "+999.9999" is stored.
• When the comparator value is under range, "-999.9999" is stored.
• When the comparator value is invalid, "-999.9998" is stored.
• When an error occurs, "+1000.0000" is stored.
*3 When you use the calculation function and calculation setting is set to other than
standard difference display, a reading error occurs on the expansion unit.