3-2 I/O Communication
3-7
3
Communicating with the GT2 series
- DeviceNet Compatible Network Unit DL-DN1 User’s Manual (GT2) -
"5-output + current value" mode
The device map varies depending on the operating mode of the DL-DN1.
Access each device in a manner suitable for the selected operating mode.
"Status" (page 3-7)
"Output" (page 3-9)
"Comparator Value (P.V. Value)" (page 3-10)
"External input" (page 3-11)
"Changing a bank" (page 3-13)
"Rewrite setting value" (page 3-14)
Status
IN area
n: The first device number assigned to the DL-DN1
5-output + current
value
No extended mode Yes - - -
5-input - Yes Yes Yes
Bank change - - Yes -
Setting value rewrite - - - Yes
Area IN OUT IN OUT IN OUT IN OUT
Number of sensor
amplifi ers
1 18
0
28
10
32
14
40
40
2 22 32 36 44
3 26 36 40 48
4 30 40 44 52
5 34 44 48 56
6 38 48 52 60
7 42 52 56 64
8 46 56 60 68
9 50 60 64 72
10 54 64 68 76
11 58 68 72 80
12 62 72 76 84
13 66 76 80 88
14 70 80 84 92
15 74 84 88 96
(b
ytes)
Device Maps
Device
(DEC)
Name
Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8
n Status
Reserved Reserved Reserved
Error ID
number
(MSB)
Error ID
number
Error ID
number
Error ID
number
Error ID
number
(LSB)
Error state Reserved
Sensor
ready
Error code
(MSB)
Error code Error code Error code
Error code
(LSB)
Comentarios a estos manuales