E GL-R-IM
Current consumption
*1 The above current consumption does not include the current consumed via OSSD output.
*2 If inputs other than EDM input turn on, consumption current per input increases by 2.5 mA.
Weight
Troubleshooting
If the GL-R is not functioning normally, check the GL-R indicators first.
The GL-R is in an error condition under the following situations.
The center indicators blink in red.
The 7-segment display indicates "".
If the GL-R does not demonstrate the above situations, the GL-R is not in an error condition.
If the GL-R is in an error condition
*1 All indicators on the transmitter may turn OFF.
*2 This error occurs only when the muting lamp error is configured to cause error condition by using the
configuration software.
Indication Error name Cause Check and corrective action
Wiring error
The end cover on the
receiver is not connected.
Check that the end cover is installed on the receiver
correctly.
"Cable installation" (page 5)
The unit connection cable
is connected to the upper
part of the GL-R.
Connect the unit connection cable to the lower part of
the GL-R.
"Cable installation" (page 5)
Transmitter and receiver
are not the same model.
Check that all transmitter and receiver models are
paired correctly.
When the GL-R operates in wire synchronization system
The synchronization wire is
not wired correctly or
disconnected.
Check the wiring of the synchronization wire.
"Cable color and pin position" (page 6)
When the GL-R operates in one-line system
The unit connection cable
is connected to the
transmitter.
Connect the unit connection cable to the receiver.
Do not connect the unit connection cable to the
transmitter.
"Cable installation" (page 5)
The series connection
cable is connected to the
lower part of the GL-R.
Connect the series connection cable to the upper part
of the transmitter and receiver.
"Cable installation" (page 5)
When the GL-R is in series connection.
The sub unit is not
connected correctly.
Check for the direction of the sub unit installation.
Check whether the receiver of sub unit is connected
to the transmitter of main unit.
Check whether the total number of beam axes is
more than 240.
"Series connection" (page 4)
The sub unit is broken.
Check that the sub unit operates correctly when not in
series connection.
When the error is cleared by restarting the GL-R.
The synchronization wire is
affected by external noise.
Check for noise source (inverter, servomotor, etc.)
around the GL-R installation location and cables.
Units: mA Units: mA Units: mA
Model
Current
consumption (Max.)
Transmitter
Receiver
GL-R23F 50 70
GL-R31F 54 71
GL-R39F 57 72
GL-R47F 60 74
GL-R55F 62 75
GL-R63F 64 77
GL-R71F 66 78
GL-R79F 67 80
GL-R87F 69 81
GL-R95F 71 83
GL-R103F 72 84
GL-R111F 74 85
GL-R119F 76 87
GL-R127F 78 89
Model
Current
consumption (Max.)
Transmitter
Receiver
GL-R08H 43 66
GL-R12H 46 68
GL-R16H 50 69
GL-R20H 53 71
GL-R24H 57 72
GL-R28H 59 73
GL-R32H 61 74
GL-R36H 63 75
GL-R40H 65 76
GL-R44H 66 77
GL-R48H 68 79
GL-R52H 69 80
GL-R56H 71 81
GL-R60H 72 82
GL-R64H 73 83
GL-R72H 75 85
GL-R80H 77 87
GL-R88H 79 89
GL-R96H 81 91
Model
Current
consumption (Max.)
Transmitter
Receiver
GL-R04L 37 66
GL-R06L 39 67
GL-R08L 41 68
GL-R10L 43 69
GL-R12L 46 70
GL-R14L 48 71
GL-R16L 50 72
GL-R18L 52 73
GL-R20L 54 75
GL-R22L 56 75
GL-R24L 57 76
GL-R26L 59 77
GL-R28L 60 78
GL-R30L 61 79
GL-R32L 62 80
Units: g Units: g Units: g
Model
Weight
Transmitter
Receiver
GL-R23F 320 330
GL-R31F 430 440
GL-R39F 550 550
GL-R47F 660 670
GL-R55F 780 780
GL-R63F 890 900
GL-R71F 1000 1010
GL-R79F 1200 1200
GL-R87F 1300 1300
GL-R95F 1400 1400
GL-R103F 1500 1500
GL-R111F 1600 1600
GL-R119F 1700 1700
GL-R127F 1800 1900
Model
Weight
Transmitter
Receiver
GL-R08H 210 210
GL-R12H 320 330
GL-R16H 430 440
GL-R20H 550 550
GL-R24H 660 660
GL-R28H 770 770
GL-R32H 880 890
GL-R36H 1000 1000
GL-R40H 1110 1110
GL-R44H 1220 1220
GL-R48H 1330 1340
GL-R52H 1440 1450
GL-R56H 1560 1560
GL-R60H 1670 1680
GL-R64H 1780 1790
GL-R72H 2010 2010
GL-R80H 2230 2240
GL-R88H 2450 2460
GL-R96H 2680 2690
Model
Weight
Transmitter
Receiver
GL-R04L 210 210
GL-R06L 320 330
GL-R08L 430 440
GL-R10L 550 550
GL-R12L 660 660
GL-R14L 770 770
GL-R16L 880 890
GL-R18L 1000 1000
GL-R20L 1110 1110
GL-R22L 1220 1220
GL-R24L 1330 1340
GL-R26L 1440 1450
GL-R28L 1560 1560
GL-R30L 1670 1680
GL-R32L 1780 1790
Setting switch error
The configuration of the
setting switch is out of
specification.
Check the configuration of the setting switch.
"Setting switch" (page 3)
The setting switch is
configured to something
other than Channel 0 in
wire synchronization
system.
Configuration error
The configuration of the
setting switch overlaps the
configuration uploaded
from the configuration
software.
Modify the configuration of the setting switch or modify
the configuration by the configuration software.
"Setting switch" (page 3)
The unit configuration is
different from the
configuration uploaded
from the software.
Check the model name of main unit and sub unit and
whether the unit configuration from the software is
identical to the actual unit configuration.
The upload of configuration
has not been completed
correctly when using the
configuration software.
Upload the configuration again.
Interlock error
Interlock mode selection
input or reset input are
wired incorrectly.
Rewire the interlock mode selection input or reset input
correctly.
"Examples of Wiring" (page 6)
EDM error
EDM input is not
connected correctly.
If EDM function is needed, rewire the EDM correctly.
If EDM function is not needed, rewire the EDM and
AUX correctly or deactivate the EDM function by the
configuration software.
"Examples of Wiring" (page 6)
There is a welded contact
on the external device.
Replace the external device.
Receiver error
The receiver is affected by
ambient light.
Shield the receiver from ambient light.
Transmitter error
The transmitter is broken. Replace the transmitter.
When the error is cleared by restarting the GL-R.
The transmitter is affected
by external noise.
Check for a noise source (inverter, servomotor, etc.)
around the GL-R installation location and cables.
OSSD1 error
OSSD2 error
When the error is cleared by restarting the GL-R.
OSSD is affected by
external noise.
Check for a noise source (inverter, servomotor, etc.)
around the GL-R installation location and cables.
There is a voltage surge
affecting the OSSD due to
an inductive load.
When the load is inductive such as relay, use a load
with a surge absorption device.
The power supply voltage
has fallen continuously or
experienced a sudden
drop.
Take measures by replacing the power supply,
increasing the power capacity, or dedicating the power
supply to the GL-R.
When the error is not cleared by restarting the GL-R.
OSSD is short-circuited
to 0 V or 24 V of power
supply.
OSSDs are short-
circuited to each other.
OSSD is short-circuited
to other wires.
Rewire the OSSD correctly.
"Examples of Wiring" (page 6)
Too much current is
flowing through the OSSD.
Check that the load does not consume more current
than the OSSD can handle.
"Specifications" (page 9)
OSSD is broken. Replace the receiver.
Sub unit error
The sub unit is broken. Replace the sub unit.
When the error is cleared by restarting the GL-R.
The sub unit or series
cable is affected by
external noise.
Check for a noise source (inverter, servomotor, etc.)
around the GL-R installation location and cables.
Communication error
*1
When the error is cleared by restarting the GL-R.
The synchronization wire is
not wired correctly or is
disconnected.
Check the connection of the synchronization wire.
The synchronization lines
in the cable are affected by
external noise.
Check for a noise source (inverter, servomotor, etc.)
around the GL-R installation location and cables.
The power supply voltage
has fallen continuously or
experienced a sudden
drop.
Take measures by replacing the power supply,
increasing the power capacity, or dedicating the power
supply to the GL-R.
When the error is not cleared by restarting the GL-R.
The synchronization wire is
not connected correctly or
is disconnected.
Check the connection of the synchronization wire.
The connection with the
GL-R in series is broken.
Replace the GL-R unit connected in series.
"Series connection" (page 4)
Muting lamp
disconnection error
*2
The muting lamp is not
connected correctly.
Check the connections.
The muting lamp is broken. Replace the muting lamp.
Muting lamp over
current error
*2
The muting lamp is not
connected correctly.
Check the connections.
Too much power is
consumed by the muting
lamp.
Make sure the muting lamp does not consume more
power than the GL-R can handle.
The muting lamp is broken. Replace the muting lamp.
Synchronization beam
axis error
When the GL-R operates in
optical synchronization
system, the fixed blanking
or muting function is
applied to both the upper
and lower beam axes (for
synchronization control).
Do not apply the fixed blanking or muting function to
at least the upper or lower axis.
Make the GL-R operate in one-line system or wire
synchronization system.
"Wiring system" (page 3)
:
System error
The power supply voltage
has fallen continuously or
experienced a sudden
drop.
Take measures by replacing the power supply,
increasing the power capacity, or dedicating the power
supply to the GL-R.
The GL-R is broken. Replace the GL-R.
Indication Error name Cause Check and corrective action