Keyence CV-X Series Manual de usuario Pagina 5

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 22
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 4
KEYENCE CORPORATION. Vision System Division
5 www.keyence.com
Select [PLC] > [Transfer] >[To PLC].
5
4
Open [IO Table and Unit Setup] on the left side of the screen, and register the Ethernet link unit in an empty slot.
Double-click the registered Ethernet link unit (CJ1W-ETN21 in this example) to edit the parameters.
Configure the following settings in [Edit Parameters].
1. For [FINS/UDP Port], select "9600", the default value (the default value is also 9600 for CV-X).
2. Set [IP Address/Subnet Mask]. Enter the "IP Address" set in CV-X Global Settings.
3. Enter the CV-X NODE No. and IP Address into [IP Address Table] (the default CV-X NODE No. of 001 is recommended).
4. Set [Port No.] to 0.
After completing the settings, press "OK".
Vista de pagina 4
1 2 3 4 5 6 7 8 9 10 ... 21 22

Comentarios a estos manuales

Sin comentarios