IV Series (Sensor) - IM_E
Short-range type
50
0
100
150
10 20 30 4012 36
View H (mm)
Installed distance WD (mm)
Long-rang type
View H (mm)
Installed distance WD (mm)
500
300
0
1500
1000
2000
10045 200 300 400
The value of View H and V will be a half of the value on
the gures above when using the digital zooming function
(monochrome type only).
Mounting the mounting adapter
Use the mounting adapter (accessory or OP-87460) to
mount the sensor.
The mounting adapter is mounted on the
sensor in the default factory setting. Remove
it from the sensor.
“Unmounting the sensor” (Page 5)
Mounting on the wall
Screw : M3 x 4
Use the commercially available screws which have head
thickness of 3 mm or lower.
Tightening torque : 1.0 N·m or lower
Mounting from the jig side
Screw : M4 x 4
Use the commercially available screws.
Tightening torque : 1.5 N·m or lower
For details on mounting hole dimensions, refer
to “Dimensions” (Page 8).
Mounting the sensor onto the mounting adapter
1
Mount the sensor to the left and right stopper on
the mounting adapter.
Sensors cannot be mounted on the side with the
indicator light.
Push the sensor to the
stopper of xing screw
Push until you hear the clicking
sound from the both side stoppers
Indicator light
2
Fix the mounting adapter and sensor using the
attached screws.
Screw : M3 x 1
Use the attached screws.
Tightening torque : 0.45 to 0.55 N·m
Remove the protection
sheet (blue)
Unmounting the sensor
1
Dismount the screw.
2
Pull out the stopper of the mounting adapter and
unmount the sensor.
Pull out the
stopper