IV Series (Monitor) - IM_E
Precautions on installation
To use the IV-M30 correctly and safely, avoid
installing it in the following locations. Failure
to do so may cause re, electric shock, or
malfunction.
Outdoors
Altitude above 2000 m
Locations that are humid, dusty or poorly
ventilated
Locations where the temperature is high
such as those exposed to direct sunlight
Locations where there are ammable or
corrosive gases
Locations where the unit may be directly
subjected to vibration or impact
Locations where water, oil, or chemicals
may splash onto the unit
To improve the anti-noise feature, install
the unit following the precautions below.
Otherwise, a malfunction may occur.
Do not mount the unit in a cabinet where
high-voltage equipment is already installed.
Mount the unit as far from power lines as
possible.
Separate the unit as far as possible from the
devices that emit strong electric or magnetic
eld (such as solenoid or chopper).
Separate the I/O signal line from the power
line or high-voltage line.
For power supply
Noise superimposed on the power supply
could cause malfunction. Use a stabilized
DC power supply congured with an
isolation transformer.
When using a commercially available
switching regulator, be sure to ground the
frame ground terminal.
Devices including this unit are precision
components. Do not apply shock or vibration.
When connecting to a network, let engineers
who are knowledgeable about networks
handle it.
Precautions on Regulations and Standards
UL Certication
This product is a UL/C-UL Listed product.
UL File No. E207185
Category NRAQ, NRAQ7
Be sure to consider the following specications when using
this product as a UL Listed product
Use a power supply with Class 2 output dened in
NFPA70 (NEC: National Electrical Code).
This product is for use on a at surface of a Type 1 enclosure.
CE Marking
Keyence Corporation has conrmed that this product complies with
the essential requirements of the applicable EC Directive, based
on the following specications. Be sure to consider the following
specications when using this product in the Member State of
European Union.
EMC Directive (2004/108/EC)
Applicable Standard EMI : EN61326-1, Class A
EMS : EN61326-1
The length of Monitor power cable, Ethernet cable and
Monitor cable must be less than or equal to 30m.
Remarks:
These specications do not give any guarantee that the
end-product with this product incorporated complies
with the essential requirements of EMC Directive. The
manufacturer of the end-product is solely responsible
for the compliance on the end-product itself according to
EMC Directive.
Checking the Package Contents
Intelligent Monitor
IV-M30
Monitor x 1
Stylus x 1
String for hanging the stylus x 1
Wall mounting adapter x 1
Screw for adapter x 2
Hexagon nut x 2
Instruction Manual x 1
(This manual)
Starting Guide x 1
Options for Monitor
Monitor power cable (M8 4pin - strand wire)
OP-87443 (2m)
OP-87444 (5m)
OP-87445 (10m)
Monitor power cable (M8 4pin - strand wire) x 1
USB memory (1GB)
OP-87502
USB memory x 1
Protection sheet
OP-87463
Protection sheet x 1
Stylus
OP-87462
Stylus x 1
String for hanging the stylus x 1
Same as accessories for monitors.
Optional parts in case of loss/damage.